Highlight:

bms aging test chamber

,

bms new energy solutions

,

new energy aging test chamber

Warranty Period:
12 Months
Aging Quantity:
36
Rated Working Current:
32A
Warranty Period:
12 Months
Aging Quantity:
36
Rated Working Current:
32A
Product Description

New Energy Pure Electric Vehicle BMS Module Aging Test Experimental Cabinet

 

 

 
Performance parameters
New Energy Pure Electric Vehicle BMS Module Aging Test Experimental Cabinet 0
 
Skills requirement Burn-in cabinet size(mm) L1600*W1100*H1600
Rated working voltage 380Vac
Rated insulation voltage 690Vac
Rated frequency 50Hz
Rated working current 32A
Power frequency withstand
voltage for 1 minute
2500Vac
UUT input specifications 12VDC/5Amax*36passageway
UUT output specifications Static burn-in without load
Number of burn-in stations 36 (6 layers * 6, hierarchical control)
Burn-in temperature requirements

 

Product area (50 ℃ ~ 85 ℃) can be set, ± 3 ℃ precise control

 

Temperature rise

 

Requires a temperature rise from room temperature to 85 ° C within 15 minutes. When the internal temperature is high,the surface temperature of the burn-in cabinet is below 35 °

 

Branch switch 6 way 10A/30mA/3P or 1P
Structural requirements Dimension(mm) 1600(W)*1100(D)*1600(H)
In and out line Support next in and next out
Installation method Floor installation
Burn-in slot layout requirements

 

6 layers, 6 burn-in (3 before 3) slots per layer; each layer is individually powered on

 

Monitor and indicate Monitoring requirements

 

Touch screen displays the power-on state and sensor state of each slot

 

Safety requirements

 

1.With power supply, product and other key components short-circuit, over-current field energy analysis


2.With energy analysis under over-temperature, smoke and liquid leakage scenarios


3.The control circuit has a leakage protection function


4.Possess the ability to detect and operate ground faults and leakage faults


5.PLC control, real-time monitoring of burn-in cabinet status

 

Panel instructionsv Status indicator of each slot