logo

Shenzhen CPET Electronics Co., Ltd. sales05@szcpet.com 86-0755-23427658

Shenzhen CPET Electronics Co., Ltd. Company Profile
Products
Home > Products > New Energy Solutions > EV Motor Controller BMS Board Burn-In Test System with 36 Stations 380Vac and 1600mm Cabinet

EV Motor Controller BMS Board Burn-In Test System with 36 Stations 380Vac and 1600mm Cabinet

Product Details

Place of Origin: China

Brand Name: CPET

Model Number: CP-BMS02

Payment & Shipping Terms

Minimum Order Quantity: 2sets

Price: 9500dollars/set

Packaging Details: Wooden case packing

Delivery Time: 45 work days

Payment Terms: L/C

Supply Ability: 30sets/month

Get Best Price
Product Details
Highlight:

bms burn in test

,

bms burn in equipment

,

motor controller burn in test

Trolley Size (mm):
L1600*W1100*H1600
Warranty:
1 Year
Weight:
400kg
Trolley Size (mm):
L1600*W1100*H1600
Warranty:
1 Year
Weight:
400kg
Product Description
EV Vehicle Motor Controller BMS Battery Management System Board Burn In Test
Product Description

The EV Vehicle Motor Controller BMS (Battery Management System) Board Burn-In Test equipment is designed for rigorous high-temperature testing of vehicle motor controller BMS boards.

Scope of Application
EV Motor Controller BMS Board Burn-In Test System with 36 Stations 380Vac and 1600mm Cabinet 0

This equipment is primarily used for high temperature burn-in testing of BMS boards for vehicle motor controllers.

Performance Parameters
EV Motor Controller BMS Board Burn-In Test System with 36 Stations 380Vac and 1600mm Cabinet 1
Parameter Specification
Burn-in cabinet size (mm) L1600 * W1100 * H1600
Rated working voltage 380Vac
Rated insulation voltage 690Vac
Rated frequency 50Hz
Rated working current 32A
Power frequency withstand voltage for 1 minute 2500Vac
UUT input specifications 12VDC/5Amax * 36 passageway
UUT output specifications Static burn-in without load
Number of burn-in stations 36 (6 layers * 6, hierarchical control)
Burn-in temperature requirements Product area (50℃ ~ 85℃) can be set, ±3℃ precise control
Temperature rise Requires temperature rise from room temperature to 85℃ within 15 minutes. Surface temperature below 35℃ when internal temperature is high
Environment control Circulation air control, hot air prohibited from direct discharge to workshop
Master switch Route 1 32A
Branch switch 6 way 10A/30mA/3P or 1P
Noise <70dB (measured at 1m distance)
Structural requirements Dimension(mm): 1600(W) * 1100(D) * 1600(H)
In and out line Support next in and next out
Installation method Floor installation
Burn-in slot layout 6 layers, 6 burn-in slots per layer (3 before 3); each layer individually powered
Docking method Cable flexible connection
Cabinet door Front and rear double doors
Maintenance method Front, back, left and right maintenance
Monitoring and Safety Features
  • Monitoring: Touch screen displays power-on state and sensor state of each slot
  • Safety: Power supply, product and key components short-circuit/over-current field energy analysis
  • Protection: Energy analysis under over-temperature, smoke and liquid leakage scenarios
  • Control: Leakage protection function in control circuit
  • Detection: Ground fault and leakage fault detection capability
  • Automation: PLC control with real-time monitoring of burn-in cabinet status
Panel Instructions

Includes status indicator for each slot.

Our Products