logo

Shenzhen CPET Electronics Co., Ltd. sales05@szcpet.com 86-0755-23427658

Shenzhen CPET Electronics Co., Ltd. Company Profile
Products
Home > Products > Charger and Adapter Aging Rack Machine > Industrial High Power Burn-In Testing Facility with 72 Loads 1500W and 54KW Capacity

Industrial High Power Burn-In Testing Facility with 72 Loads 1500W and 54KW Capacity

Product Details

Place of Origin: China

Brand Name: CPET

Model Number: CP-HPA02

Payment & Shipping Terms

Minimum Order Quantity: 2sets

Price: 9000dollars/set

Packaging Details: Wooden case packing

Delivery Time: 40 work days

Payment Terms: L/C

Supply Ability: 30sets/month

Get Best Price
Product Details
Highlight:

Industrial burn in testing

,

Charger Adapter burn in testing

,

Industrial burn and test

Warranty:
12 Months Free Warranty
Single Channel Minimum Load Current:
≤0.5A
Maximum Power Consumption At Full Load:
<15KW
Warranty:
12 Months Free Warranty
Single Channel Minimum Load Current:
≤0.5A
Maximum Power Consumption At Full Load:
<15KW
Product Description
Industrial High Power Charger Adapter Burn-In Testing Facility
Scope of Application
Industrial High Power Burn-In Testing Facility with 72 Loads 1500W and 54KW Capacity 0

This burn-in testing system is designed for comprehensive testing of various AC-DC adapters under controlled environmental conditions.

Performance Parameters
Industrial High Power Burn-In Testing Facility with 72 Loads 1500W and 54KW Capacity 1
Parameter Specification
Capacity Maximum feedback power of burn-in products: 54KW@1000A
Full load feedback efficiency >85%
Maximum power consumption at full load <15KW
Number of channels 6 floors with 12 channels of 1500W each
Number of loads 6 layers, 12 loads per layer (72 total loads CP8503)
Single channel minimum load current ≤0.5A
Available space per floor Length ≥1.8m, depth ≥0.5m
Equipment environment Temperature -10~55℃, humidity 0~95%
Input Requirements
  • Input voltage: Each layer uses DC-48 power supply (-48V voltage range 38.5~72V)
  • Switch control: Each layer equipped with contactors (1 per 3 stations), remotely controlled with 200ms cycle capability
  • Input cable: Must meet 105℃ high temperature requirements and full power flow requirements
  • Input terminal: Copper wire routing guarantees current flow at full load (max 50A per tested module)
  • Auxiliary source: 12 interfaces per layer (12V, 2A+), isolated for monitoring board and fans
Output Requirements
  • Output voltage: 3~60Vdc
  • Load mode: CC (Constant Current)
  • Output current: 1500W @ 120A (±3% accuracy), minimum 0.5A, adjustable in 0.1A steps
  • Voltage reporting: Error less than ±0.2V
  • Output sockets: 8 terminals per station (≥20A flow capacity)
Temperature Control
  • Internal working temperature range: Room temperature ~70℃
  • Heating time to 70℃: ≤30 minutes
  • Temperature control zones: One per two floors (±3℃ deviation)
  • Sustained operation capability at all working temperatures