5G Base Station Communication Power Supply Burn In Chamber with 60CH Capacity and Flammability Rating V0

Product Details

Place of Origin: China

Brand Name: CPET

Model Number: CP-5G03

Payment & Shipping Terms

Minimum Order Quantity: 2sets

Price: 8800dollars/set

Packaging Details: Wooden case packing

Delivery Time: 30 work days

Payment Terms: L/C

Supply Ability: 30sets/month

Get Best Price
Product Details
Highlight:

1200W/CH aging test machine

,

Power Supply aging test machine

,

1200W/CH aging test chamber

Reference Size (D*W*H):
1000*600*1700mm
Burn-in Test Capacity:
1200W/CH
Guarantee Period:
1year
Reference Size (D*W*H):
1000*600*1700mm
Burn-in Test Capacity:
1200W/CH
Guarantee Period:
1year
Product Description
1200W/CH 5G Base Station Communication Power Supply Aging Test Equipment
Product Description
5G Base Station Communication Power Supply Aging Test Equipment is designed for comprehensive burn-in testing of power supply systems in 5G communication infrastructure.
Scope of Application
5G Base Station Communication Power Supply Burn In Chamber with 60CH Capacity and Flammability Rating V0 0
This system meets burn-in requirements for 5G communication energy products including:
  • Low-voltage three-phase 4KW power products
  • Single-phase 6KW power products
  • Compatible with 2KW and energy board power product testing
A complete burn-in test system includes:
  • Burn-in cabinet product cabinet (with temperature control, power distribution, and monitoring)
  • Burn-in distribution cabinet
  • Load system
Performance Parameters
5G Base Station Communication Power Supply Burn In Chamber with 60CH Capacity and Flammability Rating V0 1
Parameter Specification
Reference size (D*W*H) D1000mm*W600mm*H1700mm
Burn-in test capacity 1200W/CH, 60CH
Rated working voltage AC: 380VAC/Three-phase +10%/-15%
Rated insulation voltage 690VAC
Rated frequency 50Hz
Rated working current Input: 360A
Operating temperature 5℃-45℃
Output channel specifications 380VAC/Three-phase 60A
Protective function Supports smoke detection, over temperature protection, and three-color light status display
Monitoring rate Digitally collected information refresh interval < 1S
Smoke sensor type Overhead installation type smoke sensor, normally closed point work
Flammability rating All cabinet materials meet 99-V0 rating
Temperature rise of power distribution components Complies with IEC 60947-1, temperature rise value within standard requirements
Leakage Protection 30mA leakage protection circuit installed on AC side
Monitoring/instruction requirements 19-inch LCD display with keyboard/mouse interface, computer monitoring system
The human-machine interface displays PLC-collected temperature, control status, system status, fan operation status, DD & DA equipment status, cabinet input AC power and other information. DD & DA status query and setting are monitored by the test monitoring board.