Shenzhen CPET Electronics Co., Ltd. sales05@szcpet.com 86-0755-23427658
Product Details
Place of Origin: China
Brand Name: CPET
Model Number: CP-CNC02
Payment & Shipping Terms
Minimum Order Quantity: 2sets
Price: 8550dollars/set
Packaging Details: Wooden case packing
Delivery Time: 40 work days
Payment Terms: L/C
Supply Ability: 30sets/month
Warranty: |
12 Months |
Trolley Size (mm): |
L2050*W700*H2050mm |
Trolley Structure Material: |
Hick Cold Rolled Sheet |
Warranty: |
12 Months |
Trolley Size (mm): |
L2050*W700*H2050mm |
Trolley Structure Material: |
Hick Cold Rolled Sheet |
| Burn-in Cabinet Structure and Burn-in Quantity Planning | |
|---|---|
| Trolley size (mm) | L2050*W700*H2050mm (size of a single Burn-in cabinet) |
| Number of trolley layers | 4 layers, product area depth 400mm (12 Burn-in positions per layer) |
| Trolley height | 350mm |
| Trolley structure material/appearance color | 2.0mm thick cold rolled sheet, computer white |
| Load area cooling method | Top turbine exhaust fan top row type (easy to control the ambient temperature) |
| Layer insulation and anti-static method | Epoxy insulation board with heat dissipation holes on the surface |
| Overall burn-in room structure | Mobile Burn-in split cabinet; beautiful appearance and easy to move and combine |
| Configuration Parameter | Specification |
|---|---|
| Energy recovery module control mode | RS485 communication mode, upper computer uses RS232 communication mode |
| Install the power module model | CP8102/CP8104 |
| Number of energy-consuming load modules installed | Each layer has 6 4CH modules, 24 modules in entire burn-in cabinet |
| Install the energy recovery module model | CP8401+CP5312 (See specification for details) |
| Energy recovery module isolation mode | Electronic load module channel adopts photoelectric isolation (communication and power supply isolation) |
| Number of energy recovery modules installed | Three 4CH modules per floor, 12 modules in entire cabinet, plus 6 single-phase 5KW inverter modules |
| Energy recovery module design architecture | No relay, long-life design scheme (independent intellectual property rights) |
| Number of burn-in products in the whole cabinet | 24 energy storage power supplies with eight DC outputs (50W/100V/5A) and AC outputs (220V/500W) aged in one cabinet |