Shenzhen CPET Electronics Co., Ltd. sales05@szcpet.com 86-0755-23427658
Product Details
Place of Origin: China
Brand Name: CPET
Model Number: CPET-AT3888S03
Payment & Shipping Terms
Minimum Order Quantity: 2sets
Price: 32000dollars/set
Packaging Details: Wooden case packing
Delivery Time: 48 work days
Payment Terms: L/C
Supply Ability: 1sets/month
Warranty: |
1 Year |
Equipment Size: |
1300*200*270cm |
Equipment Weight: |
3000kg |
Warranty: |
1 Year |
Equipment Size: |
1300*200*270cm |
Equipment Weight: |
3000kg |
LED power supply, new energy OBC, PC power supply, server power supply, TV power supply, photovoltaic inverter, high-power industrial power supply, etc.
| Basic Information | ||
|---|---|---|
| Model | Equipment Model | CPET-AT3888S |
| Units Per Hour (UPH) | 1600PCS/H or 56PCS/H | |
| Product Power | 5W~65W/CH or 1000W~3000W/CH | |
| Equipment Size | L=13000MM, W=2000MM, H=2700MM | |
| Equipment Weight | Approximately 3000kg | |
| Burn-in Room Capacity | 3888PCS or 280PCS |
| Burn-in Time | 2H |
| Burn-in Ply Number | 9 floors |
| Transfer Mode | Similar to tridimensional storage/manipulator transportation/connector contact |
| Cooling Circulation Mode | Forced air cooling: fan + frequency converter + air duct |
| Control Scope and Precision | Adjustable from room temperature to 60°C (±5°C precision) |
| Temperature Rise Rate | Reaches above 45°C in 20 minutes |
| Product and Load Properties | Optional |
| Burn-in Voltage Input | Supports up to 6 voltages |
| Protection and Alarm | Independent power control with overheating, overload, and earth leakage protection |
| Test Station Types | Integrated product installation, electrified initial test, high voltage, ATE, burn-in, and product removal |
| Test Mode | Optional |
| Test Data Processing | Optional |
| Test Instruments | Optional |
| Jig Size | L500*W300*H30MM3 (18 bits per vehicle or customized) |
| Interface Mode | AC: Universal socket; DC: USB or conventional DC female socket or customized |
| Common Usage | Shared by burn-in and test |
| Weight | 1.5kg |
| Protection Equipment | Independent segmentation main switches with ground and electricity leakage protection |
| Power Demands | According to actual planning |
| Air Source Requirements | 5-8KGF/CM3 |