Shenzhen CPET Electronics Co., Ltd. sales05@szcpet.com 86-0755-23427658
Product Details
Place of Origin: China
Brand Name: CPET
Certification: CE,ROHS
Model Number: CPET-ME4800020T
Payment & Shipping Terms
Minimum Order Quantity: 1
Price: 42000
Packaging Details: Packed in wooden cases
Delivery Time: 60 work days
Payment Terms: T/T
Supply Ability: 2 sets/ month
Capacity Of The Aging Room: |
80PCS |
Average Output(UPH): |
200PCS/h |
Capacity Of The Aging Room: |
80PCS |
Average Output(UPH): |
200PCS/h |
LED power supplies, new energy OBC, PC power supplies, server power supplies, TV power supplies, photovoltaic inverters, high-power industrial power supplies, etc.
| Basic Information | |
|---|---|
| Equipment Model | CPET-ME4800020T |
| Average Output (UPH) | 200PCS/h |
| Product Power | 5W~65W/CH or 1000W~3000W/CH |
| Equipment Size | L=8800mm, W=1800mm, H=1950mm |
| Equipment Weight | 2600KG |
| Aging Line Specifications | |
|---|---|
| Aging Room Capacity | 80PCS |
| Aging Time | 1H |
| Number of Aging Layers | 5 |
| Transfer Method | Modular splicing mechanical hand handling |
| Temperature Control System | |
|---|---|
| Cooling Circulation Mode | Air cooling: fan + frequency converter + air duct |
| Control Range and Accuracy | Adjustable from room temperature to 60℃ (±5℃ accuracy) |
| Heating Rate | Can rise above 45°C within 20 minutes |
| Electrical Control System | |
|---|---|
| Product and Load Characteristics | Optional |
| Input Aging Voltage | Supports up to six voltages |
| Protection and Alarm | Includes fuses, overheat/overload protection, leakage protection, warning lights, and emergency switches |
| Software Requirements | |
|---|---|
| Hardware Requirements | Independent computer host for monitoring output voltage, current, power, etc. |
| Software Monitoring | Custom aging programs for different products with parameter control |
| Aging Management | Data saving in TXT/EXCEL formats for easy query and download |
| Test Station Information | |
|---|---|
| Test Procedure | Product loading + initial power-on test + high voltage + ATE + aging + ATE + product retrieval |
| Test Method | Optional |
| Test Data Processing | Optional |
| Aging & Testing Fixtures | |
|---|---|
| Fixture Size | W390mm * D470mm * H100mm |
| Interface Mode | AC: Universal socket DC: USB or regular DC female socket or custom |
| Universality | Shared aging test capability |
| Weight | 6KG |
| Main Electrical Control System | |
|---|---|
| Protective Device | Segmented main switches with independent grounding and leakage protection |
| Electricity Demand | According to actual plan |
| Gas Source Demand | 0.5-0.8MPa |